Worcester Bosch Ea Worcester Bosch 30cdi Boiler With Intermittant EA Fault.?

Worcester Bosch 30cdi boiler with intermittant EA fault.? - worcester bosch ea

Already has more than 2 years and a fine of 6 EA went very intermittent fault then months.Started more frequently.
Worcester Bosch Engineers, said the low gas pressure of 32 mm pipe underground had supplied to the boiler and improved in recent Transco pipelines on the way back, but the blame more from EA.
In all 8 or 9 visits from Worcester Bosch, but not avail.Coming 26/11.

Always check that the pressure in the boiler with all gas appliances in homes with gas and fast that the pressure to say goodbye low.When Transco pressure increase.

Without doubt, these boilers operate under low pressure?. Code around 5:00 sometimes without other gases.
Who ideas.

Thankss

Chris.

2 comments:

Turdy malurdy said...

A pressure regulator has been renewed on the counter?

pipe strangler said...

2 Your questions answered. First Transco only worry you have enough pressure on the subway, which is over 18-22 MB with 3 burners on a gas stove or boiler operation, if it has no kitchen. Secondly, who should not) the operating pressure in the boiler (input be smaller than 1 MB less than the pressure of work in the subway, in other words, if the meter should not be less than 20 mo 21MB boiler. Working within the limits allowed if you have less than 17mb is in the pocket, then you have a problem with pipes similar to a long of 32 mm during the installation. Are there lots of accessories in the race, because each round has a resistance value of the straight tube about 1 / 2 feet of hose. And no, you do not operate at low pressure.